Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37675801

RESUMO

BACKGROUND AND OBJECTIVE: Diagnostic criteria of chronic rhinosinusitis with nasal polyps (CRSwNP) include, among others, olfactory dysfunction (OD). We hypothesize that patients suffering with CRSwNP are good at self-assessing their sense of smell through visual analogue scale (VAS) compared to smell tests. METHODS: A controlled cross-sectional study was planned. Adults diagnosed with severe CRSwNP waiting for endoscopic sinus surgery were included. A cohort of healthy controls was also studied. All participants performed Barcelona smell test (BAST-24), sinonasal outcomes test 22 (SNOT-22), and VAS for loss of smell. CRSwNP underwent blood test (eosinophils count, total serum IgE), CT scan (Lund-Mackay Score), and nasal endoscopy. RESULTS: 138 severe CRSwNP and 40 controls subjects were included. The BAST-24 identification score was strongly correlated with the VAS score in the CRSwNP group (rho=-0.79, p<0.001) but not in the control group (rho=-0.14; p=0.39), this difference between groups being statistically significant (p<0.001). A significant correlation of SNOT-22 item 21 (loss of smell) was also found with BAST-24 identification (rho=-0.65, p<0.001), this difference being statistically significant (Z=-2.43; p=0.015). In the ROC curve, the area under the curve (AUC) was 0.85 with 72.5% sensitivity and 93.1% specificity. CONCLUSION: This study demonstrates a potential role of the VAS score for the screening of OD in severe CRSwNP in daily clinical practice.

2.
Rhinology ; 60(5): 347-356, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36184882

RESUMO

BACKGROUND: Sinonasal mucosal melanoma is an aggressive malignancy with a 5-year survival rate ranging from 20% to 39%. Despite the evolving surgical and radiotherapy techniques, and introduction of immune-checkpoint inhibitor therapy, overall survival rates remain poor. METHODOLOGY: A retrospective cohort study was conducted at the Hospital Clinic de Barcelona and the Hospital de la Santa Creu i Sant Pau between 1984 and 2020; primary outcome measures were 3 and 5-year melanoma-specific survival (MSS). Kaplan-Meier survival analysis and Cox proportional hazards model were performed to identify predictors of survival. RESULTS: Fifty patients were included, the mean age was 70.4, MSS at 3 and 5 years was 51.2%, and 29.5%, respectively. The median follow-up was 39.6 months during which 46% presented locoregional recurrence and 36%, metastasis. The univariate and multivariate analyses found as survival predictors the N category, the treatment received, the surgical margins and the mitotic index. CONCLUSIONS: We found an overall 5-year MSS of 29.5%. Those patients with intention-to-cure (stages III and IVa) treated by surgery that were N0 at diagnosis, with < 10 mitoses per HPF showed a 5-year MSS rate of 74.1%. More studies will be needed to adequately define the patients' profiles that will benefit from a better survival outcome.


Assuntos
Melanoma , Neoplasias dos Seios Paranasais , Idoso , Intervalo Livre de Doença , Humanos , Inibidores de Checkpoint Imunológico , Melanoma/cirurgia , Recidiva Local de Neoplasia/patologia , Neoplasias dos Seios Paranasais/patologia , Neoplasias dos Seios Paranasais/cirurgia , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida
3.
J Investig Allergol Clin Immunol ; 32(4): 291-298, 2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35532333

RESUMO

BACKGROUND AND OBJECTIVE: Most smell tests are difficult to implement in daily clinical practice owing to their long duration. The aim of the present study was to develop and validate a short, easy-to-perform, and reusable smell test to be implemented during the COVID-19 pandemic. METHODS: The study population comprised 120 healthy adults and 195 patients with self-reported olfactory dysfunction (OD). The 8-Odorant Barcelona Olfactory Test (BOT-8) was used for detection, memory/recognition, and forced-choice identification. In addition, a rose threshold test was performed, and a visual analog scale was applied. The Smell Diskettes Olfaction Test (SDOT) was used for correlation in healthy volunteers, and the University of Pennsylvania Smell Identification Test (UPSIT) was used for patients with OD to establish cut-offs for anosmia and hyposmia. In order to take account of the COVID-19 pandemic, disposable cotton swabs with odorants were compared with the original test. RESULTS: In healthy persons, the mean (SD) BOT-8 score was 100% for detection, 94.5% (1.07) for memory/recognition, and 89.6% (0.86) for identification. In patients with OD, the equivalent values were 86% (32.8), 73.2% (37.9), and 77.1% (34.2), respectively. BOT-8 demonstrated good test-retest reliability, with agreement of 96.7% and a quadratic k of 0.84 (P<.001). A strong correlation was observed between BOT-8 and SDOT (r=0.67, P<.001) and UPSIT (r=0.86, P<.001). Agreement was excellent for disposable cotton swabs, with a k of 0.79 compared with the original test. The cut-off point for anosmia was ≤3 (area under the curve, 0.83; sensitivity, 0.673; specificity, 0.993). CONCLUSION: BOT-8 offers an efficient and fast method for assessment of smell threshold, detection, memory, and identification in daily clinical practice. Disposable cotton swabs with odorants proved to be useful and safe during the COVID-19 pandemic.


Assuntos
COVID-19 , Transtornos do Olfato , Adulto , Anosmia , COVID-19/epidemiologia , Humanos , Odorantes , Transtornos do Olfato/diagnóstico , Transtornos do Olfato/epidemiologia , Pandemias , Reprodutibilidade dos Testes , Olfato
4.
J. investig. allergol. clin. immunol ; 32(4): 291-298, 2022. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-208241

RESUMO

Background: Most smell tests are difficult to implement in daily clinical practice owing to their long duration. The aim of the present study was to develop and validate a short, easy-to-perform, and reusable smell test to be implemented during the COVID-19 pandemic. Methods: The study population comprised 120 healthy adults and 195 patients with self-reported olfactory dysfunction (OD). The 8-Odorant Barcelona Olfactory Test (BOT-8) was used for detection, memory/recognition, and forced-choice identification. In addition, a rose threshold test was performed, and a visual analog scale was applied. The Smell Diskettes Olfaction Test (SDOT) was used for correlation in healthy volunteers, and the University of Pennsylvania Smell Identification Test (UPSIT) was used for patients with OD to establish cut-offs for anosmia and hyposmia. In order to take account of the COVID-19 pandemic, disposable cotton swabs with odorants were compared with the original test. Results: In healthy persons, the mean (SD) BOT-8 score was 100% for detection, 94.5% (1.07) for memory/recognition, and 89.6% (0.86) for identification. In patients with OD, the equivalent values were 86% (32.8), 73.2% (37.9), and 77.1% (34.2), respectively. BOT-8 demonstrated good test-retest reliability, with agreement of 96.7% and a quadratic k of 0.84 (P<.001). A strong correlation was observed between BOT-8 and SDOT (r=0.67, P<.001) and UPSIT (r=0.86, P<.001). Agreement was excellent for disposable cotton swabs, with a k of 0.79 compared with the original test. The cut-off point for anosmia was ≤3 (area under the curve, 0.83; sensitivity, 0.673; specificity, 0.993). Conclusions: BOT-8 offers an efficient and fast method for assessment of smell threshold, detection, memory, and identification in daily clinical practice. Disposable cotton swabs with odorants proved to be useful and safe during the COVID-19 pandemic (AU)


Introducción: Las olfatometrías son difíciles de implementar en la práctica clínica diaria por su larga duración. El objetivo del presente estudio fue desarrollar y validar una prueba simple, fácil y reutilizable para ser utilizada durante la pandemia de COVID-19. Métodos: Se incluyeron 120 voluntarios sanos ≥18 años y 195 pacientes con disfunción olfatoria (DO) autoreportada. Se utilizó el Barcelona Olfactory Test (BOT-8) con 8 odorantes para la detección, memoria/reconocimiento e identificación. Además, se hizo una prueba de umbral de rosa (alcohol feniletílico) de 6 diluciones, escala visual analógica (EVA). Se compararon los resultados con una prueba validada Smell Diskettes Olfaction Test (SDOT), para definir puntos de corte de hiposmia y anosmia se comparó en pacientes con DO con UPSITTM. Considerando la pandemia de COVID-19, se compararon hisopos de algodón desechables con los odorantes respecto a la prueba original. Resultados: BOT-8 se tarda entre 3 y 7 minutos en realizar. En población sana, la media de detección fue del 100%, memoria 94,5% (DE=1,07) e identificación 89,6% (DE=0,86). En pacientes con DO fue de 86% (DE=32,8), 73,2% (DE=37,9) y 77,1% (DE=34,2), respectivamente. BOT-8 demostró buena fiabilidad test-retest con 96,7% de concordancia observada y una kappa cuadrática de 0,84 (p<0,001). Presentó una fuerte correlación con SDOT (r=0,673, p <0,001) en población sana y con UPSITTM en pacientes con DO (r=0,86, p<0,001). Los hisopos de algodón desechables mostraron una excelente concordancia (kappa de 0,79) en comparación con la prueba original. El punto de corte para anosmia fue ≤ 3 (AUC=0,83, Se= 0,673, Sp=0,993) y de hiposmia ≤ 6 (AUC=0,451, Se= 0,088, Sp= 0,814). Conclusiones: BOT-8 ofrece un método eficiente y rápido para ser utilizado en la práctica clínica diaria para evaluar el sentido del olfato mediante la detección, memoria, identificación y umbral (AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Transtornos do Olfato/diagnóstico , Infecções por Coronavirus/complicações , Pneumonia Viral/complicações , Pandemias , Odorantes , Reprodutibilidade dos Testes , Transtornos do Olfato/virologia
5.
Rhinology ; 56(4): 386-392, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30033453

RESUMO

BACKGROUND: The nasal floor and inferior meatus (NFIM) flap represents an available option for the reconstruction of a septal perforation (SP). This study explores the feasibility of repairing SPs using a modified simple and extended (including inferior turbinate) NFIM flap. METHODS: An anatomic study was achieved in fresh frozen cadaveric specimens to measure the area and lengths of NFIM flap. The repair of SP with simple and extended NIFM flaps was performed in some of these cadaveric specimens. Preoperative radiological evaluation of CT scans allowed studying the reconstruction limits of the simple or extended NFIM flap. A cohort of patients with SP who underwent reconstruction with an NFIM flap was also included. RESULTS: Complete SP repair with NFIM was achieved in all specimens (n=10). In 38 fresh cadaveric specimens, coronal and sagittal lengths and area of simple NFIM flaps were smaller than in extended NFIM flaps. The radiological analysis of 75 CT scans revealed that the septal height could be reconstructed with a simple and extended NFIM flap. Complete SP repair wasachieved in 5 patients (4 male, mean age 57.4 years) using modified NFIM flaps. CONCLUSION: The simple or expanded NFIM flap represents a feasible option to repair small or medium-sized perforations located at the lower 1/3 or 3/4 of the nasal septum.


Assuntos
Perfuração do Septo Nasal/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Retalhos Cirúrgicos , Idoso , Idoso de 80 Anos ou mais , Cadáver , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Perfuração do Septo Nasal/diagnóstico por imagem , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...